Adhesive tapes for ECG Electrodes and Neutral Electrodes

Ease of converting, adhesive cohesion, backing flatness, adhesion performance on all types of skin, compatibility between adhesive and gel … the adhesive supports for ECG electrodes and ESU plates designed by Adhex comply with biocompatibility standards.

The electrode backings designed by Adhex (Foam, non-woven, or films) meet the requirements of electrocardiogam or electroencephalogram examinations: long tests (holter from 48 to 72 hours) or stress tests (about 30 minutes). In addition, our range is composed of supports that have been validated for neutral electrode application. The adhesion performances ensures an optimal holding of the electrode or or the plate on any type of skin and in all atmospheric conditions (heat, humidity) without adhesive residues on the patient’s body. Our adhesive have been formulated with a high skin tolerance, avoiding irritation, itching and redness. The balance of stripping load forces between the adhesive and the release liner prevents from tearing when our materials are passed through the electrode converting machine. In addition, the performance of Adhex solutions avoids problems related to curling (folds) that can cause machine downtime. Easy to convert, lengths allow productivity gains and the widths are adjustable according to the cutting tool and the dimensions of the final electrode. Finally, the initial liner can be reused on the final product. The entire range has undergone all biotoxicity tests (ISO-10993 standard).

Our adhesive backings designed for ECG and Neutral Electrodes

P916

Single coated white PE foam

  • Carrier: White PE foam 1 mm (55 kg/m3)
  • Adhesive: Solvent acrylic 35 g/sqm
  • Liner: White paper, one side siliconized 80 g/sqm
  • Higher skin adhesion
  • Long lasting skin adhesion
  • Suitable for ECG electrodes

P918

Single coated white PE foam

  • Carrier: White PE foam 1 mm
  • Adhesive: Solvent free acrylic 40 g/sqm
  • Liner: White paper one side siliconized 63 g/sqm
  • Medium skin adhesion
  • Eco-friendly adhesive
  • Suitable for neutral electrodes
  • Good combination with P828 hydrogel

P576

Single coated white PP non-woven laminated with PP film

  • Carrier: White PP non-woven laminated with PP film 65 g/sqm
  • Adhesive: Solvent free acrylic 50 g/sqm
  • Liner: White paper one side siliconized 80 g/sqm
  • Good skin adhesion
  • Eco-friendly adhesive
  • Suitable for neutral electrodes 

We developp a wide range of adhesive backings for various monitoring applications, why not yours ?

Find our range of tapes for sensors and monitoring applications